Collecting data from ECDIS systems

ECDIS systems are connected to at least GPS and gyro and typically also to other sensors like the speed log and wind sensor. Most ECDIS systems are capable of sending this data through a serial port or over a TCP/IP connection, but this may require configuration of the system. TECDIS Furuno FMD Can be configured to pass navigation data to a serial port or over network in IEC61162-450 format. The following data fields are known to work: - Position, course over ground, spee...

Introduction

The installation of TelScope consists of the following steps - Preparation on shore (https://Telko.liveagent.se/495278-Shore-Preparation) Sets up the communication channel between the on board server(s) and the data center on shore. For a dual installation the communication channel between the on board is also prepared in this step. This requires general internet access and we highly recommend that this is done before installing the computers on board the vessel. - Physical installatio...

Shore Preparation

Before installing the TelScope computers on board, the shore connection must be initialized. For a dual installation, this must be done for both the TelScope computers. We highly recommend to do this on shore before installing the computers on the vessel. The server needs general internet access to complete this step. Accessing the configuration tool - Connect a display, keyboard and mouse to the computer and connect the computer to internet. - Turn on the computer. It will log in au...

Physical installation Telscope

The Guide To Good WORKMANSHIP An engineer handbook containing Telko product installation guidelines Installation of Telko Products: Server (2224 C): Ground Server Ground power cable shield Use cable markings Use bolt, washer and nut when mounting Use wire markings Add some extra cable before connecting to the contacts on the Server Displays: Ground Display Ground power cable shield Use cable markings Use bolt, washer and nut when mounting Keyboard/Tr...

Server setup

The goal of the on board server initialization is to prepare the connections to the network(s) on board, the data sensors and the dual computer. The server initialization takes places in the config tool, so a display, keyboard and mouse must be connected to the computer. For details about how to access the config tool, see Accesing the config tool (https://Telko.liveagent.se/495278-Shore-Preparation#accessing-the-config-tool). When this process is completed, the TelScope software is ready to b...

TelScope setup

To make the TelScope system fully operational this following parts must be configured: - Set the ship time offset - Set up data collection. - Add roles - Add users and assign roles - Configure log books The system indicates that it is fully operational with a green symbol in the top left corner of the screen. If checklists have been prepared by the ship owner we recommend to add them at this point. - Add checklists